AIRLOCK
Rotary valves operating under dryers, calcining kilns, boiler ash outlets and hot gas filters behave differently from equipment at normal ambient temperature. As the temperature rises, the rotor and housing expand at different rates; a clearance set for ambient temperature can cause the rotor to rub against the housing at operating temperature.
In DOSERAY high-temperature rotary valves, the rotor-to-housing clearance is calculated for the operating temperature. The bearings are positioned away from the housing (outboard), and the seals and lubrication are selected for temperature resistance. Where necessary, a cooling jacket or heat shield is added to the housing.
What is a high-temperature rotary valve and where is it used?
Hot products are often abrasive as well. For this reason, Ni-Hard or Hardox housings and hardened rotor options are also considered for high-temperature models.
-







-
Eductors and Self-Cleaning Rotary Valves
Although in some processes the rotary valve is used within the pneumatic conveying system, the pipe inlet and outlet directions can cause problems during maintenance; dismantling the pipes for maintenance is undesirable. In such plants, instead of a blow-through rotary valve (airlock), a standard rotary feeder can be used with a venturi-effect device fitted underneath. This way the connected lines do not have to be dismantled when servicing the rotary valve, giving the process greater flexibility.
- In some processes, requirements may not fit any standard or size. Various factors such as restricted height or flowability problems may call for different solutions when selecting a rotary valve.
In such cases, a series-connected rotary valve arrangement, also known as a tandem or multiway port rotary valve, comes into play.
Mounting rotary valves in series at a restricted height offers advantages such as high capacity and feeding and discharging over a wider cross-section.
Belt feeding, spreading raw material onto belt conveyors and square-section cone discharges are among the main applications.
Multiway rotary valve
-
-
Rotary Valves and Air Leakage
This topic often leads to misunderstandings and incorrect use. It should be remembered that every rotary valve needs a running clearance in order to rotate, which means there is a gap between the housing and the rotor. On leaving the factory, this clearance is generally set to 0.15–0.30 mm on all rotary valves. If the system performs pneumatic conveying and the conveyed material is somewhat abrasive, this clearance can increase over time. Increased clearances can lead to air leaking upwards through the rotary valve (blow-back) and to bridging problems.
- To prevent such situations, the leakage air must be vented, especially in blow-through rotary valves. If venting is done correctly, rotary valves can operate without problems with wear up to a clearance of 1 mm. That is why venting of the leakage air and the orientation of the rotary valve are important on all pneumatic conveying lines. Otherwise, performance problems arise in the system even with very slight wear.
-
- For airlocks in processes with a risk of wear, vane thickness, high-alloy steel vanes, end covers, speed and the venting of leakage air are important. Product selection therefore needs careful attention from the outset.
.
Rotary Valve Technical Dimensions
The connection flanges are compatible with our standard range; because the bearing distance is greater, the overall length is longer than that of the standard model.
Standard Rotary Valve Models
Most standard models can be produced in a high-temperature version with suitable clearances and bearings.
Rotary Valve Capacity Table

At high temperatures, the bulk density and flow behaviour of the product can change. Let us work with you to select the capacity based on your product's data under operating conditions.